NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
440
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Machine data
Table 11-38 Referencing: Machine data
Number
Name
Name
General ($MN_ ... )
11300
JOG_INC_MODE_LEVELTRIGGRD
INC/REF in jog/continuous mode
Channelspecific ($MC_ ... )
20700
REFP_NC_START_LOCK
NC-Start disable without reference point
Axisspecific ($MA_ ... )
30200
NUM_ENCS
Number of encoders
30240
ENC_TYP
Actual value encoder type
30242
ENC_IS_INDEPENDENT
Encoder is independent
31122
BERO_DELAY_TIME_PLUS
BERO delay time in plus direction
31123
BERO_DELAY_TIME_MINUS
BERO delay time in minus direction
34000
REFP_CAM_IS_ACTIVE
Axis with reference cam
34010
REFP_CAM_DIR_IS_MINUS
Reference point approach in minus direction
34020
REFP_VELO_SEARCH_CAM
Reference point approach velocity
34030
REFP_MAX_CAM_DIST
Maximum distance to reference cam
34040
REFP_VELO_SEARCH_MARKER
Reference point creep speed
34050
REFP_SEARCH_MARKER_REVERSE
Direction reversal to reference cam
34060
REFP_MAX_MARKER_DIST
Maximum distance to reference mark; Maximum distance to two
reference marks with distance-coded scales
34070
REFP_VELO_POS
Reference point positioning velocity
34080
REFP_MOVE_DIST
Reference point distance/destination point for distancecoded
system
34090
REFP_MOVE_DIST_CORR
Reference point/absolute offset, distancecoded
34092
REFP_CAM_SHIFT
Electronic reference cam shift for incremental measurement
systems with equidistant zero marks.
34100
REFP_SET_POS
Reference point value
34102
REFP_SYNC_ENCS
Actual value adjustment to the referencing measurement system
34110
REFP_CYCLE_NR
Axis sequence for channel-specific Homing
34120
REFP_BERO_LOW_ACTIVE
Polarity change of BERO
34200
ENC_REFP_MODE
Referencing mode
34210
ENC_REFP_STATE
Status of absolute encoder
34220
ENC_ABS_TURNS_MODULO
Absolute encoder range for rotary encoders
34300
ENC_REFP_MARKER_DIST
Reference marker distance with distancecoded scales
34310
ENC_MARKER_INC
Interval between two reference marks with distancecoded scales
34320
ENC_INVERS
Linear measuring system inverse to machine system
34330
REFP_STOP_AT_ABS_MARKER
Distance-coded linear measuring system without destination
destination point
35150
SPIND_DES_VELO_TOL
Spindle speed tolerance
36302
ENC_FREQ_LIMIT_LOW
Encoder limit frequency resynchronization
36310
ENC_ZERO_MONITORING
Zero mark monitoring
30250
ACT_POS_ABS
Absolute encoder position at time of deactivation.
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...