Default values
The default values of the acceleration are in the range of 0.5 m/s
2
to 2 m/s
2
.
Checking the acceleration
The sign of a properly adjusted acceleration of a machine axis is acceleration and
positioning free from overshoot at rapid traverse rate and maximum load (heavy workpiece).
After the acceleration has been entered, the axis is traversed rapidly and the actual current
values and current setpoint are recorded.
Note
•
SINAMICS
The current actual value/setpoint can be recorded using the STARTER trace function.
•
SIMODRIVE
The current actual value/setpoint can be recorded using the trace function of SimoCom
U.
The online help provides more detailed information.
This recording shows whether the drive reaches the current limit. Here, the current limit can
be reached for a short time.
The current must be well below the current limit, however, before the rapid traverse velocity
or the final position is reached.
Load changes during machining must not cause the current limit to be reached. Excessive
current during machining causes falsification of the contour. For this reason, the acceleration
value should be a little bit less than the maximum acceleration value.
Machine axes can have different acceleration values, even if they interpolate with each other.
Machine data
Table 11-32 Position control: Machine data
Number
Name
Name/remarks
Axisspecific ($MA_ ... )
32100
AX_MOTION_DIR[n]
Traversing direction
32110
ENC_FEEDBACK_POL[n]
Actual value sign
32200
POSCTRL_GAIN [n]
Kv factor
32300
MAX_AX_ACCEL[n]
Axis acceleration
32900
DYN_MATCH_ENABLE[n]
Dynamic response adaptation
32910
DYN_MATCH_TIME [n]
Time constant for dynamic matching
References:
/FB/ Function Manual - Basic Functions, G2 Velocities, Setpoint/Actual Value Systems,
Control, Chapter "Control"
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...