PLC commissioning
6.6 Load configuration (STEP 7 -> PLC)
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
179
6.6
Load configuration (STEP 7 -> PLC)
6.6.1
Requirements
For loading the configuration into the PLC, the following prerequisites must be fulfilled:
●
A communications link exists between STEP 7 and the PLC.
●
The configuration to be loaded corresponds to the actual station configuration.
●
SINUMERIK 840Di sl is active:
–
NC: Cyclic operation
–
PLC: RUN or STOP mode
6.6.2
Uploading the configuration
Note
It is recommended to check consistency of the configuration before loading it.
HW Config: Station > Check consistency
Supplementary condition
The following boundary conditions regarding the system data blocks are observed when the
configuration is loaded:
●
SIMATIC Manager
When loading the configuration via the SIMATIC manager all the system data blocks are
loaded into the module.
●
HW Config
When loading the configuration via HW Config, only the system data blocks generated by
HW Config during compilation of the configuration are loaded into the module.
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...