Hardware Descriptions
2.4 Cable distributor
Manual
68
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Pin assignments
Connector designation: X1...X10
Plug-connector type: DU-BOX-plug connectors
Table 2-10 Pin assignment of cable distributor
Pin-No.
37-pin
plug
Signal name DU-BOX-
plug
Pin. No./
Cable
No.
Cable order No.
6FX2002-4AA....
Wire color
I/O device
Terminal
9
10
-
MEPUS 0
-
MEPUC 0
X10/2
X10/1
X10/4
X10/3
7
41-0❑❑❑
rd
or
bn
bk
Shielding
1. Measuring
inputs
1. Measuring
inputs
24V
Reference 0V
1
20
2
21
M24EXT
P24EXT
M24EXT
P24EXT
X9/2
X9/1
X9/4
X9/3
6
41-0❑❑❑
rd
or
bn
bk
Shielding
Supply of the 4
binary outputs/of
the MPI
connector
Chassis
ground
24 V
Chassis
ground
24 V
3
22
4
23
OUTPUT 1
OUTPUT 3
OUTPUT 0
OUTPUT 2
X8/2
X8/1
X8/4
X8/3
5
41-0❑❑❑
rd
or
bn
bk
Shielding
4 binary outputs 2. Output
4. Output
1. Output
3. Output
5
24
6
25
7
26
8
27
INPUT 3
GNDEXT
INPUT 2
GNDEXT
INPUT 1
GNDEXT
INPUT 0
GNDEXT
X7/2
X7/1
X7/4
X7/3
X6/2
X6/1
X6/4
X6/3
4
21-0❑❑❑
rd
or
bn
bk
green
yellow
vt
bu
Shielding
4 binary inputs
4. Input
Chassis
ground
3. Input
Chassis
ground
2. Input
Chassis
ground
1. Input
Chassis
ground
28
29
-
MEPUS 1
-
MEPUC 1
X5/2
X5/1
X5/4
X5/3
3
41-0❑❑❑
rd
or
bn
bk
Shielding
2. Measuring
inputs
2. Measuring
inputs
24V
Reference 0V
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...