PLC commissioning
6.3 Creating a SIMATIC S7 project
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
165
NOTICE
If the interface X102 is not networked with PROFIBUS, then it must at least be networked
with MPI, in order to enable the internal communication via SOFTMC. See Subsection
"Parameterizing the MPI interface (X102) (optional)" (Page 169)
6.3.5
Parameterizing the PROFIBUS interface (X101)
When you have inserted the 840Di sl Rack, the dialog box for assigning parameters to the
PROFIBUS interface (X101) opens automatically as for slot X2. Make the following settings
in the Properties box:
●
PROFIBUS address of the DP master
The default setting of the PROFIBUS address is 2. It is recommended to retain this
setting.
●
Subnet
●
Equidistant DP cycle
●
Equidistant time
Equidistant time
The set equidistant DP cycleis accepted in case of SINUMERIK 840Di sl as NC system clock
cycle and position controller cycle.
Position controller cycle = NC system clock cycle = equidistant DP cycle
The time you can set for the equidistant DP cycle depends on:
1.
The cyclic communication load by the drives and field devices on the PROFIBUS DP
2.
The capacity utilization of the cyclic position controller level by the NC due to the number
of position-controlled machine axes and active functions
Dialog
Dialog: Properties - PROFIBUS interface DP
Tab: Parameter
Address: 2
Subnet:
Button: "New..."
Dialog: Properties - New Subnet PROFIBUS
Tab: General
S7 subnet ID: <Subnet ID> (see below: Note)
Tab: Network settings
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...