Ethernet communication
7.4 External HMI Advanced
Manual
190
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Note
There are no restrictions in terms of Ethernet topology within the SINUMERIK 840Di sl PCU
and HMI PCU.
Requirements
The following requirements must be fulfilled:
●
There is an Ethernet connection between SINUMERIK 840Di sl PCU and HMI PCU and
both computers communicate.
●
The communication parameters of the SINUMERIK 840Di sl PCU Ethernet interface with
which the HMI PCU is connected are known.
To check an Ethernet connection, see Subsection "Check Ethernet
HMI configuration
The configuration of HMI Advanced, with respect to the Ethernet connection to the
SINUMERIK 840Di sl, is performed as follows:
1.
Start HMI Advanced.
2.
Open the dialog for entering the IP address: Operating area switchover > Startup > HMI >
NCU link > NCU address
3.
Enter the IP address of the interface by which the HMI communicates with the
SINUMERIK 840Di sl.
Example:
Interface: Ethernet 2 (system network)
IP Address: 192.168.214.241 (default)
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...