NC Commissioning with HMI Advanced
11.2 Machine and setting data
Manual
362
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Number Name
Name
9219
USER_CLASS_TEACH_IN
TEACH IN
9220
USER_CLASS_PRESET
PRESET
9221
USER_CLASS_CLEAR_RPA
Deleting R parameters
9222
USER_CLASS_WRITE_RPA
Write R parameters
9231
USER_CLASS_WRITE_RPA_1
Write protection for first RPA area
9232
USER_BEGIN_WRITE_RPA_1
Start of the first RPA area
9233
USER_END_WRITE_RPA_1
End of the first RPA area
9234
USER_CLASS_WRITE_RPA_2
Write protection for second RPA area
9235
USER_BEGIN_WRITE_RPA_2
Start of the second RPA area
9236
USER_END_WRITE_RPA_2
End of the second RPA area
9237
USER_CLASS_WRITE_RPA_3
Write protection for third RPA area
9238
USER_BEGIN_WRITE_RPA_3
Start of the third RPA area
9239
USER_END_WRITE_RPA_3
End of the third RPA area
9240
USER_CLASS_WRITE_TOA_NAME
Change tool designation and duplo
9241
USER_CLASS_WRITE_TOA_TYPE
Change tool type
9247
USER_CLASS_BASE_ZERO_OFF_PA
Basic offset PA
9248
USER_CLASS_BASE_ZERO_OFF_MA
Basic offset MA
References:
/FB/ Function Manual, Basic Functions, A2 various Interface Signals, Chapter "MMC
Machine data for protection levels"
Single data units
The protection level of individual machine and/or setting data can be modified in the file
SGUD.DEF.
Example:
The axial machine data item CTRLOUT_SEGMENT_NR requires protection level 3 for
reading and protection level 2 for writing.
Syntax:
REDEF $
machine data string APR n APW m
APR n: Defining the protection level for reading (Read) the data
APW m: Defining the protection level for writing (Write) the data
SGUD.DEF file:
%_N_SGUD_DEF
;$PATH=/_N_DEF_DIR
REDEF $MA_CTRLOUT_SEGMENT_NO APR 3 APW 2
M30
References:
/PGA/ Programming Manual, Work Planning, Chapter "File and Program Administration",
defining protection levels for user data (GUD)
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...