NC Commissioning with HMI Advanced
11.3 System data
Manual
368
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
User-defined
The user can define different input/output units for machine and setting data.
For this there must be an adjustment between the newly selected input/output units and the
internal units via the following MD:
●
MD10220 $MN_SCALING_USER_DEF_MASK (activation of standardizing factors) and
●
MD10230 $MN_SCALING_FACTORS_USER_DEF[n] (standardizing factors of the
physical quantities)
<HV
1R
,QWHUQDOVFDOLQJ
0'
6FDOLQJIDFWRUDFWLYDWHG"
0'6FDOLQJIDFWRU
,QWHUQDOSK\VLFDOXQLW
,QSXWYDOXHVIRUPDFKLQHGDWD
The following applies:
Selected I/O unit =
MD10230 $MN_SCALING_FACTORS_USER_DEF[n] * internal unit
The selected I/O unit, expressed in the internal units 1 mm, 1 degree and 1 s must therefore
be entered in MD10230 $MN_SCALING_FACTORS_USER_DEF[n].
Table 11-6 Bit number and index for user definition
Physical unit
MD10220:
Bit number
MD10230:
Index n
Linear position
0
0
Angular position
1
1
Linear velocity
2
2
Angular velocity
3
3
Linear acceleration
4
4
Angular acceleration
5
5
Linear jerk
6
6
Angular jerk
7
7
Time
8
8
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...