Troubleshooting Using Status Indicators
Insertion Blink
The insertion blink is three successive blinks of a hot-swap component's primary status
indicator (for example, the green OK indicator). The insertion blink occurs immediately after
three successive unison blinks (see
“Slow Unison Blink Rate” on page 79
component indicators.
Unison Steady On
For the unison steady on, all indicators are simultaneously steady on (see
. This occurs during the front panel lamp test (see
). This is the only time that the Locate Button/LED indicator is on steady.
Alternating (Invalid FRU) Blink Rate
The alternating (invalid FRU) blink rate is a repeating sequence of lit green and amber
indicators at 1 Hz. This indicates that a component has an incorrect version or mismatch (for
example, a power supply with a lower rating than the one specified). The blink rate is also used
for an unsupported component, or a component in an unsupported slot.
80
Oracle Server X7-8 Service Manual • October 2017