Remove a Power Supply
■
Back Power Supply Fault-Service Required LED located on the server front panel FIM
Call
Out
Status LED or Button
Icon and
Color
Description
1
Fault-Service Required
Locate LED
Amber
White
Indicates the location of the power supply in the
server:
■ Off – Power supply is operating normally,
■ Fast blink – Use Oracle ILOM to activate this
LED to enable you to locate a power supply
quickly and easily.
Lights steady on when the power supply is in a fault
state.
2
OK
Power Supply OK LED (green)
Green
Indicates the functional state of the power supply:
■ Off – PS is disconnected
■ Steady On – PS is powered on and functionaing
normally. When this LED is lit, the AC OK LED
is also lit.
Note -
Oracle ILOM signals a fault on any installed
power supply that is not connected to an AC power
source, since it might indicate a loss of redundancy.
3
AC OK LED (green)
~AC
Green
Indicates the operational state of the power supply:
■ Off – PS is not connected to an AC power
source.
142
Oracle Server X7-8 Service Manual • October 2017