9 - 10
9 REAL MODE/VIRTUAL MODE SWITCHING AND STOP/RE-START
9.4.1 Stop operation/stop causes during operation and re-starting operation list
Table 9.5 Stop Operation/stop Causes during Operation and Re-starting Operation List
Affected virtual axis
Stop processing
No.
Stop operation or stop
causes during operation
Virtual
servomotor axis
Synchronous
encoder axis
All axes
batch
Virtual
servomotor axis
Synchronous
encoder axis
Return to Real mode
by operating system
software after all virtual
axes stop completion
Synchronization
discrepancy warning
(M2046) set
1 Stop command ON
(Applicable axis)
— —
Deceleration
stop
—
—
—
2 Rapid stop command ON
(Applicable axis)
— —
Rapid
stop —
—
—
3
All-axes servo OFF
command
(M2042 OFF, Command
using MT Developer2 in
the TEST mode)
— —
Deceleration
stop
Immediate
input stop
(Note-1)
— —
4
PLC ready flag (M2000)
OFF
— —
Deceleration
stop
Immediate
input stop
(Note-1)
—
5 Motion
CPU
stop
—
—
Deceleration
stop
Immediate
input stop
(Note-1)
—
6
All-axes rapid stop from
MT Developer2
— —
Rapid
stop
Immediate
input stop
(Note-1)
— —
7
Stop from
MT Developer2 in the
TEST mode
(All axes)
— —
Deceleration
stop
—
—
—
8 Forced
stop
—
—
Rapid
stop
Immediate
input stop
(Note-1)
9
Servo error at output
module even if 1 axis
— —
Rapid
stop
Immediate
input stop
(Note-1)
10 Motion
CPU
WDT
error
—
—
Immediate
stop
Immediate
input stop
— —
11
Multiple CPU system
reset
— —
Immediate
stop
Immediate
input stop
— —
12
Multiple CPU system
power OFF
— —
Immediate
stop
Immediate
input stop
— —
13
Other errors during virtual
axis operation
—
—
Deceleration
stop
—
—
—
14
Error detection at
absolute synchronous
encoder axis
—
— —
Immediate
input stop
— —
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......