8 - 12
8 OUTPUT MODULE
(6) Torque limit value setting device (1 word)
(a) This device is used to set the torque limit value of ball screw axis.
When the device is set, the torque control is executed with the preset device
value.
In the virtual mode, the torque limit setting is always valid.
If the device is not set, the torque limit is set at 300[%].
(b) The following devices can be set as the torque limit value setting device.
Name Setting
range
Data register
D0 to D8191
(Note-1)
Link register
W0 to W1FFF
Motion register
#0 to #7999
Multiple CPU area device
U \G10000 to U \G(10000+p-1)
(Note-2)
(Note-1): D800 to D1559 are dedicated devices of virtual servomotor axis,
synchronous encoder axis and output module "Cam" in the virtual mode.
Unused areas of virtual servomotor axis and cam axis can be used as a
user device.
(Note-2): "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
(c) The setting range for the torque limit value is 1 to 1000[%].
(7) Comment
(a) This device is used to create a comment such as purpose of ball screw axis.
Made comment can be displayed at monitoring using MT Developer2.
(b) Comments up to 32 characters long can be created.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......