APP - 65
APPENDICES
(b) Q173DCPU(-S1)/Q172DCPU(-S1)
Q173DCPU(-S1)/Q172DCPU(-S1)
Operation
cycle
[ms]
0.44 0.88 1.77 3.55 7.11 14.2
"WAIT ON/OFF"
+ Motion control step
0.88 1.77 2.66 4.44 7.99 15.11
Only Motion control step
1.0 to 1.4
1.9 to 2.8
2.8 to 4.6
4.6 to 8.2
8.1 to 15.2 15.2 to 29.4
Servo program
start processing
time
(Note-1)
Dedicated instruction
(D(P).SVST) from the PLC CPU
2.2 to 3.1
3.5 to 4.4
5.3 to 6.2
8.8 to 9.7
16.0 to 16.9 30.2 to 31.1
Instruction (CHGV) from the
Motion SFC
0.8 to 1.3
1.7 to 2.6
2.6 to 4.4
4.4 to 8.0
8.0 to 15.1 15.1 to 29.3
Speed change
response time
Dedicated instruction
(D(P).CHGV) from the PLC CPU
1.7 to 2.6
2.6 to 3.5
3.5 to 4.4
5.3 to 6.2
8.9 to 9.8
16.0 to 16.9
Instruction (CHGT) from the
Motion SFC
0.8 to 1.3
1.7 to 2.6
2.6 to 4.4
4.4 to 8.0
4.4 to 11.5
4.4 to 18.6
Torque limit value
change response
time
Dedicated instruction
(D(P).CHGT) from the PLC CPU
1.7 to 2.6
2.6 to 3.5
3.5 to 4.4
5.3 to 6.2
5.3 to 9.7
5.3 to 16.0
Time from PLC ready flag (M2000) ON to
PCPU READY complete flag (SM500) ON
22 to 28
(Note-1): FEED instruction varies greatly depending on the condition (whether other axes are operating).
(3) Virtual servomotor axis/synchronous encoder axis operation cycle
[ms] (Default)
(a) Q173DSCPU/Q172DSCPU
Q173DSCPU
Q172DSCPU
Number of setting axes (SV22)
1 to 6
7 to 16
17 to 32
1 to 6
7 to 16
Virtual
servomotor
[ms]
0.44 0.88 1.77 0.44 0.88
Synchronous
encoder
[ms]
0.44 0.88 1.77 0.44 0.88
(b) Q173DCPU(-S1)/Q172DCPU(-S1)
Q173DCPU(-S1)
Q172DCPU(-S1)
Number of setting axes (SV22)
1 to 4
5 to 12 13 to 28 29 to 32
1 to 4
5 to 8
Virtual
servomotor
[ms]
0.44 0.88 1.77 3.55 0.44 0.88
Synchronous
encoder
[ms]
0.44 0.88 1.77 3.55 0.44 0.88
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......