4 - 29
4 POSITIONING DEDICATED SIGNALS
(b) Command in-position check is continually executed during position control.
This check is not executed during speed control.
Command in-position
(M4003+20n)
Position
control
start
Command in-position setting
Speed
control
start
Execution of command in-position check
ON
OFF
t
V
(4) Speed controlling signal (M4004+20n) ......................... Status signal
(a) This signal turns on during speed control, and it is used as judgement of
during the speed control or position control.
The speed controlling signal that turned on with speed control turns off at
the positioning control start of following figure.
(b) This signal turns off at the power supply on and during position control.
At speed control
At position control
Speed control start
Positioning start
Speed controlling signal
(M4004+20n)
OFF
t
(5) Error detection signal (M4007+20n) ............................. Status signal
(a) This signal turns on when a minor error or major error is detected in a virtual
servomotor or output module connected to a virtual servomotor.
It is used as judgement of the error available/not available by turning the
error detection signal on/off.
(b) When the error detection signal turns on, the applicable error code is stored
in the error code storage register.
• Minor error code
(Note-1)
... Stored in the minor error code storage register
(Note-2)
.
• Major error code
(Note-1)
... Stored in the major error code storage register
(Note-2)
.
The judgement of the virtual servomotor/output module for detected error
can be confirmed by the error code details or turning the error detection
signal of output module on/off.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......