7 - 35
7 TRANSMISSION MODULE
(2) When a speed change ratio changes, the acceleration/deceleration processing is
executed by the smoothing time constant (t) set in the speed change gear
parameters.
t
E
F
C D
2500
8000
10000
t
V
V
A
B
Input axis
Speed change
ratio
Output axis
Operation
cycle
Operation
cycle
t = 100
A
B
t = 100
C
D
t = 100
E
F
Time until it becomes = 63[%]
t = 100 =
A
B
100 =
C
D
100
E
F
7.3.2 Parameters
The speed change gear parameters are shown in Table 7.3 and the parameters shown
in this table are explained in items (1) to (3) below.
Refer to the help of MT Developer2 for the speed change gear parameter setting
method.
Table 7.3 Speed Change Gear Parameter List
No.
Setting Item
Default
Setting range
1
Speed change ratio
upper limit value
10000
0 to 65535
2
Speed change ratio
lower limit value
1
0 to 65535
D0 to D8191
W0 to W1FFF
#0 to #7999
3
Speed change ratio
setting device
(1 word)
—
U \G10000 to U \G(10000+p-1)
(Note-1)
4
Smoothing time
constant
0
0 to 65535 [ms]
(Note-1): "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......