APP - 58
APPENDICES
(5) "No-clutch/clutch ON/clutch status ON" output module errors
(11000 to 11990)
Table 1.20 Output Module Error List (11000 to 11990)
Output module
Error
class
Error
code Roller
Ball
screw
Rotary
table
Cam
Error cause
Processing
Corrective action
11000
• The servo error detection signal
(M2408+20n) turned on during
operation.
After an immediate stop
at the applicable output
module, and the servo
OFF state.
• Release the servo error
causes.
(Refer to APPENDIX 1.5).
11010
• A servo OFF state (M2415+20n
OFF) during operation.
• Servo amplifier power supply was
OFF.
11020
• The stop signal (STOP) turned on.
11030
• The upper limit switch signal (FLS)
turned off during forward (address
increase direction) travel.
11040
• The lower limit switch signal (RLS)
turned off during reverse (address
decrease direction) travel.
Major
error
11050
• At the switching request to the
continuous operation to torque
control, the servo amplifier is not
compatible with the continuous
operation to torque control.
• Operation continues
at "no-clutch" axes.
• At axes with clutches,
control is executed
based on the
operation mode at the
time of the error.
• Operation continues.
• All clutches turns off
at the applicable
systems.
• When the "operation
continuation" setting is set,
execute the stop processing
using the user's Motion
SFC program.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......