10 - 5
10 AUXILIARY AND APPLIED FUNCTIONS
(4) Difference for operation between the output axis of mechanical
system program and real mode axis
Operation details for "output axis of mechanical system program" and "real mode
axis" on error are shown below.
Items
Operation for output axis of mechanical
system program
Operation for real mode axis
Feed current value
exceeds the stroke limit
range at switching from real
mode to virtual mode.
• Minor error (error code: 5000) occurs.
• Related system cannot be started.
• Minor error (error code: 105) occurs at
servo program start, and operation does
not start.
Feed current value
exceeds the stroke limit
range during operation.
• Minor error (error code: 6030) occurs.
• Operation continues.
• Minor error (error code: 207) occurs, and
deceleration stop is executed.
Output speed exceeds the
speed limit value.
• Minor error (error code: 6010) occurs.
• Speed cramp does not process by
speed limit value.
• Servo program setting error or minor
error occurs. Speed is controlled by
speed limit value.
Stop signal (STOP) is ON.
• Major error (error code: 11020)
occurs.
• Operation continues for axis without
clutch.
• Operation is controlled based on the
operation mode on error for axis with
clutch.
• Major error (error code: 1000) occurs by
turning the stop signal (STOP) on at
start, and operation does not start.
• Operation stops based on "deceleration
processing at stop" of parameter block
by turning the stop signal (STOP) on
during operation.
External upper LS signal
(FLS) turns off during travel
to forward direction
(address increase
direction).
• Major error (error code: 11030)
occurs.
• Operation continues for axis without
clutch.
• Operation is controlled based on the
operation mode on error for axis with
clutch.
• Major error (error code: 1001) occurs by
turning the external upper LS signal
(FLS) off at start to forward direction,
and operation does not start.
• Major error (error code: 1101) occurs by
turning the external upper LS signal
(FLS) off during start to forward
direction, operation stops based on
"deceleration processing at stop" of
parameter block.
External lower LS signal
(RLS) turns off during travel
to reverse direction
(address decrease
direction).
• Major error (error code: 11040)
occurs.
• Operation continues for axis without
clutch.
• Operation is controlled based on the
operation mode on error for axis with
clutch.
• Major error (error code: 1002) occurs by
turning the external lower LS signal
(RLS) off at start to reverse direction,
and operation does not start.
• Major error (error code: 1102) occurs by
turning the external lower LS signal
(RLS) off during start to reverse
direction, operation stops based on
"deceleration processing at stop" of
parameter block.
Change the torque limit
value.
• Any time valid by setting the torque
limit value setting device of output axis
and changing preset value.
• Torque limit value individual change
request instructions (D(P).CHGT2,
CHGT2) are valid.
QDS
• Torque limit value change request
instructions (D(P).CHGT, CHGT) and
torque limit value individual change
request instructions (D(P).CHGT2,
CHGT2)
QDS
are valid.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......