APP - 61
APPENDICES
Table 1.22 Real Mode/Virtual Mode Switching Error Code List (Continued)
Error codes stored in SD504
Decimal
display
Hexadecimal
display
Error description
Corrective action
515
(Note)
0203
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON in the state which the external forced
stop input signal (EMG) is ON.
• Turn the external forced stop signal off, then
turn real mode/virtual mode switching request
flag (M2043) OFF ON switching.
516
(Note)
0204
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON during the servo start processing by
the servo error reset command (M3208+20n).
• When the servo error reset is executed by
turning servo error reset command
(M3208+20n) on, turn the servo error detection
signal (M2408+20n) off, then turn real
mode/virtual mode switching request flag
(M2043) OFF ON.
768 0300
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON in the state which the home position
return signal is turning on for the output module is other
than the roller.
• Execute the home position return (execute
ZERO in the servo program), and turn real
mode/virtual mode switching request flag
(M2043) OFF ON after home position return
request signal (M2409+20n) has turned OFF.
1024 0400
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON in the state (M2408+20n ON) of the
servo error.
• Check the servo amplifier, servomotor and
wiring, etc.
1280 0500
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON in the state which the units set in the
fixed parameter and output module are different for the
output module is other than the roller.
• Correct the setting unit of the fixed parameter or
output module, and write to the Motion CPU.
1536 0600
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON in the state which cam data has not
registered although the cam is set to the output module.
• Write the cam data to the Motion CPU.
2048 0800
• Real mode/virtual mode switching request flag (M2043)
turned OFF ON without the cam No. setting to the
cam No. setting device.
(Cam No. setting device is "0").
• Turn real mode/virtual mode switching request
flag (M2043) OFF ON after writing the cam
No. set in the cam No. used of cam parameter
to the cam No. setting device.
2304 0900
• The setting value of cam stroke amount setting device is
outside the range of 1 to (2
31
-1).
• Turn real mode/virtual mode switching request
flag (M2043) OFF ON after setting the value
within the range of 1 to (2
31
-1) to the cam
stroke amount setting device.
2816 0B00
• The cam stroke amount setting device is not an even
number.
• Set an even number to the cam stroke amount
setting device.
3072 0C00
• Setting for real mode axis is not correct.
• Execute "conversion and save" after setting real
mode axis setting in the mechanical system
program editor.
3328 0D00
• The number of pulses per revolution of the rotary table
is outside the range of 1 to 1073741824.
• Correct the number of pulses per revolution and
the travel value per revolution in the fixed
parameter within the range of 1 to 1073741824
to the number of pulses per revolution of the
rotary table.
-4094
(Note)
F002
• The PLC ready flag (M2000) turned off, and the system
returned to the real mode during virtual mode operation.
• The Motion CPU stopped during virtual mode operation.
• Turn PLC ready flag (M2000) on.
• Set the Motion CPU "RUN" state.
-4095
(Note)
F001
• The servo error detection signal (M2408+20n) turned
off, and the system returned to the real mode during
virtual mode operation.
• Check the servo error code register to
determine the error cause at the axis in
question, then release the error cause
(Refer to APPENDIX 1.5).
-4096
(Note)
F000
• The forced stop signal (EMG) turned on, and the
system returned to the real mode.
• Turn the forced stop signal off.
(Note): Error axis No. information is not set to SD505, SD506 in this error.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......