4 - 41
4 POSITIONING DEDICATED SIGNALS
The start accept flag list is shown below.
Axis No.
Device No.
Axis No.
Device No.
Axis No.
Device No.
Axis No.
Device No.
1 M2001 9 M2009 17 M2017 25 M2025
2 M2002 10 M2010 18 M2018 26 M2026
3 M2003 11 M2011 19 M2019 27 M2027
4 M2004 12 M2012 20 M2020 28 M2028
5 M2005 13 M2013 21 M2021 29 M2029
6 M2006 14 M2014 22 M2022 30 M2030
7 M2007 15 M2015 23 M2023 31 M2031
8 M2008 16 M2016 24 M2024 32 M2032
(Note): The following range is valid.
• Q172DSCPU
: Axis No.1 to 16
• Q172DCPU(-S1) : Axis No.1 to 8
CAUTION
Do not turn the start accept flags ON/OFF in the user side.
• If the start accept flag is turned off using the Motion SFC program or MT Developer2 while
this flag is on, no error will occur but the positioning operation will not be reliable. Depending
on the type of machine, it might operate in an unanticipated operation.
• If the start accept flag is turned on using the Motion SFC program or MT Developer2 while
this flag is off, no error will occur but the "start accept on error" will occur at the next starting
and cannot be started.
(3) Motion error history clear request flag (M2035)
..................Command signal
This flag is used to clear the backed-up Motion error history (#8640 to #8735).
The Motion error history is cleared at leading edge of M2035.
After detection of the leading edge of M2035, the Motion error history is cleared,
and then the M2035 is automatically turned OFF.
(4) Motion SFC debugging flag (M2038) ........................... Status signal
This flag turns on when it switches to the debug mode of the Motion SFC
program using MT Developer2.
It turns off with release of the debug mode.
(5) Motion error detection flag (M2039) ............................. Status signal
This flag turns on with error occurrence of the Motion CPU.
Turn off this flag by the user side, after checking the error contents and removing
the error cause.
The self-diagnosis error information except stop error is cleared at the turning
M2039 ON to OFF.
(6) Speed switching point specified flag (M2040) ........Command signal
This flag is used when the speed change is specified at the pass point of the
constant speed control.
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......