APP - 53
APPENDICES
Table 1.16 Output Module Error List (4000 to 5990) (Continued)
Output module
Error
class
Error
code Roller
Ball
screw
Rotary
table
Cam
Error cause
Processing
Corrective action
5390
• The device set to "Number of output
axis side gear tooth count setting
device" is outside the range.
• Correct the device set to
number of output axis side gear
tooth count.
5400
• Number of input axis side gear tooth
count setting device is set to "0".
• Correct the number of input axis
side gear tooth count.
5410
• Number of output axis side gear tooth
count setting device is set to "0".
• Correct the number of output
axis side gear tooth count.
5420
• The device set to "Slippage in-position
range setting device" is outside the
range.
Related system
cannot be
started.
5430
• Slippage in-position range setting
device is outside the range (0 to
2147483647).
Control with the
setting value "0".
• Correct the device set to
slippage in-position range
setting device.
5440
• Either of "phase advance time" of
"phase compensation processing valid
flag" or "phase compensation time
constant" of the phase compensation
setting devices is outside the setting
range.
Control as the
phase
compensation
processing
invalid.
• Correct the phase advance
time.
• Correct the phase
compensation processing valid
flag.
• Correct the phase
compensation time constant.
5450
• The device set to "Smoothing clutch
complete signal device" is outside the
range.
• Correct the device set to
"Smoothing clutch complete
signal device".
5460
• The device set to "Clutch status
device" is outside the range.
• Correct the device set to "Clutch
status device".
5480
• The device set to "Cam/ball screw
switching command device" is outside
the range.
• Correct the device set to
"Cam/ball screw switching
command device".
5490
• When the address mode clutch control
system is the current value within 1
virtual axis revolution, the setting value
set to "Clutch ON address setting
device" is outside the range of "0 to
number of pulses within 1 output axis
revolution –1[PLS]".
• Correct the setting value set to
"Clutch ON address setting
device" with in the range of "0 to
number of pulses within 1
output axis revolution –1[PLS]".
5500
• When the address mode clutch control
system is the current value within 1
virtual axis revolution, the setting value
set to "Clutch OFF address setting
device" is outside the range of "0 to
number of pulses within 1 output axis
revolution –1[PLS]".
• Correct the setting value set to
"Clutch OFF address setting
device" with in the range of "0 to
number of pulses within 1
output axis revolution –1[PLS]".
5510
• The device set to "Number of pulses
per cam shaft revolution" is outside the
range.
• Correct the device set to
"Number of pulses per cam
shaft revolution".
Minor
error
5520
• The value of "Number of pulses per
cam shaft revolution" is outside the
range.
Related system
cannot be
started.
• Correct the setting of "Number
of pulses per cam shaft
revolution".
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......