10 - 1
10 AUXILIARY AND APPLIED FUNCTIONS
10
10. AUXILIARY AND APPLIED FUNCTIONS
This section describes the auxiliary and applied functions for positioning control in the
Multiple CPU system.
Items Details
Applications
Mixed function of virtual
mode/real mode
Positioning control for preset axis is
executed during synchronous
control/cam control in the
mechanical system program.
It is used in the system for which
conveys while executing synchronous
control.
10.1 Mixed Function of Virtual Mode/Real Mode
When the output axis No. to execute positioning control directly is selected in the
mixed function of virtual mode/real mode, a positioning control of axis which is not
used in the mechanical system program can be executed simultaneously during the
mechanical system program.
Example of program is shown below.
<Real mode>
[G100]
M2049//Servo ON accept?
[K10 : Real]
1 INC-1
Axis 5, 20000 PLS
Speed 200000 PLS/s
END
Motion SFC program
Transfer
Servo program
Servo amplifier
(Axis 5)
Servomotor
(Note): Motion SFC program can also be started automatically
by parameter setting.
<Virtual mode>
[G200]
M2044//on virtual mode?
[K100 : Virtual]
1 VF
Axis 1,
Speed D 0 PLS/s
END
Motion SFC program
Transfer
Servo program
Mechanical system program
Drive module (Virtual servomotor)
Transmission module
(Axis 1)
Output module
Servo amplifier
(Axis 2)
Servo amplifier
(Axis 3)
Servomotor
Servomotor
Содержание Q Series
Страница 1: ......
Страница 19: ...A 18 MEMO ...
Страница 129: ...4 90 4 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 134: ...5 5 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 139: ...5 10 5 MECHANICAL SYSTEM PROGRAM MEMO ...
Страница 163: ...6 24 6 DRIVE MODULE MEMO ...
Страница 201: ...7 38 7 TRANSMISSION MODULE MEMO ...
Страница 257: ...9 12 9 REAL MODE VIRTUAL MODE SWITCHING AND STOP RE START MEMO ...
Страница 267: ...10 10 10 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 352: ......