18.5.6 Alarm mode
The current alarm, past alarm history and parameter error are displayed. The alarm number that has
occurred or the parameter numbers in error are displayed on the display.
Name Display Description
Current alarm
Indicates no occurrence of an alarm.
2 s
interval
Indicates the occurrence of [AL. 33.1 Main
circuit voltage error].
Flickers at alarm occurrence.
The alarm number and detail number are
displayed alternately by intervals of 2s.
Alarm history
"SET"
Indicates that the last alarm is [AL. 50.1
Thermal overload error 1 during operation].
When an alarm is recorded to alarm history,
the second digit decimal point flickers.
Press and hold the "SET" button to show the
detail number of [AL. 50].
"SET"
Indicates the second last alarm is [AL. 33.1
Main circuit voltage error].
When an alarm is recorded to alarm history,
the second digit decimal point flickers.
Press and hold the "SET" button to show the
detail number of [AL. 33].
"SET"
"SET"
Indicates that there is no third alarm in the
past.
If there is no alarm history, the display will be
as shown as in the left, when the "SET"
button is pressed.
Indicates that there is no sixteenth alarm in
the past.
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......