3. SIGNALS AND WIRING
3 - 53
Normally, connect as follows.
Japan resistor
RRS10 or equivalent
DICOM
P15R
VLA
LG
SD
Servo amplifier
SP1
(Note)
2 k
Ω
2 k
Ω
24 V DC
Note. This diagram shows sink I/O interface. For source I/O interface, refer to section 3.9.3.
(b) Speed limit value selection
Select any of the speed settings by the internal speed limit 1 and by VLA (Analog speed limit) using
SP1 (Speed selection 1) as follows.
(Note) Input device
Speed command value
SP1
0
VLA (Analog speed limit)
1
Pr. PC05 Internal speed limit 1
Note. 0: Off
1: On
You can change the speed during rotation. To accelerate/decelerate, set acceleration/deceleration
time constant in [Pr. PC01] or [Pr. PC02].
When the internal speed limit 1 is used to command a speed, the speed does not vary with the
ambient temperature.
(c) VLC (Limiting speed)
As in section 3.6.3 (3) (c)
(5) Torque control in torque control mode
As in section 3.6.3 (1)
(6) Torque limit in torque control mode
As in section 3.6.3 (2)
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......