3. SIGNALS AND WIRING
3 - 31
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
P S
T
Forward rotation
stroke end
LSP
CN1-43 To start operation, turn on LSP and LSN. Turn it off to bring the motor to a
sudden stop and make it servo-locked.
Setting [Pr. PD30] to " _ _ _ 1" will enable a slow stop.
DI-1
Reverse rotation
stroke end
LSN
CN1-44
(Note) Input device
Operation
LSP LSN
CCW
direction
Positive
direction
CW
direction
Negative
direction
1
1
0
1
1
0
0
0
Note.
0:
Off
1: On
Set [Pr. PD01] as indicated below to switch on the signals (keep terminals
connected) automatically in the servo amplifier.
[Pr. PD01]
Status
LSP
LSN
_ 4 _ _
Automatic
on
_ 8 _ _
Automatic
on
_ C _ _
Automatic
on
Automatic
on
When LSP or LSN turns off, [AL. 99 Stroke limit warning] occurs, and WNG
(Warning) turns on. When using WNG, enable it by the setting of [Pr. PD23]
to [Pr. PD26], [Pr. PD28], and [Pr. PD47]. However, [Pr. PD47] is not
available with MR-J4-03A6 servo amplifiers.
In the torque control mode, this device cannot be used during normal
operation. It can be used during the magnetic pole detection in the linear
servo motor control mode and the DD motor control mode. Also, when the
magnetic pole detection in the torque control mode is completed, this
signal will be disabled.
External torque
limit selection
TL
CN1-18 Turning off TL will enable [Pr. PA11 Forward torque limit] and [Pr. PA12
Reverse torque limit], and turning on it will enable TLA (Analog torque
limit). For details, refer to section 3.6.1 (5).
DI-1
Internal torque
limit selection
TL1
To select [Pr. PC35 Internal torque limit 2/internal thrust limit 2], enable
TL1 with [Pr. PD03] to [Pr. PD22]. For details, refer to section 3.6.1 (5).
DI-1
Forward rotation
start
ST1
CN1-17 This is used to start the servo motor.
The following shows the directions.
DI-1
(Note) Input device
Servo motor starting direction
ST2
ST1
0
0
Stop
(servo-lock)
0
1
CCW
1
0
CW
1
1
Stop
(servo-lock)
Note.
0:
Off
1: On
Reverse rotation
start
ST2
CN1-18 If both ST1 and ST2 are switched on or off during operation, the servo
motor will be decelerated to a stop according to the [Pr. PC02] setting and
servo-locked.
When " _ _ _1" is set in [Pr. PC23], the servo motor is not servo-locked
after deceleration to a stop.
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......