18. MR-J4-03A6 SERVO AMPLIFIER
18 - 50
(2) Display examples
The following table shows the display examples.
Item Status
Displayed data
Servo amplifier display
Cumulative feedback pulses
720000 pulses
pulse unit
1000 pulses unit
-680000 pulses
pulse unit
Lit
The negative value is indicated by the lit decimal
points in the upper two digits.
1000 pulses unit
Lit
The negative value is indicated by the lit decimal
points in the upper two digits.
Load to motor inertia ratio
7.0 times
0.1 times
Lit
At this time, the decimal point in the second digit
flickers.
100 times
"0" in 100 times display.
15.0 times
0.1 times
Lit
At this time, the decimal point in the second digit
flickers.
100 times
"0" in 100 times display.
Position within one-revolution
4194303 pulses
pulse unit
1000 pulses unit
1000000 pulses unit