5. PARAMETERS
5 - 35
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PB51
NHQ5
Notch shape
selection 5
Set the shape of the machine resonance suppression filter 5.
When "Robust filter selection" is "Enabled (_ _ _ 1)" in [Pr. PE41], the machine resonance suppression filter 5 is not
available.
_ _ _ x Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _ For manufacturer setting
0h
PB52
VRF21
Vibration
suppression
control 2 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the setting of this digit, set "Vibration suppression mode selection" to "3
inertia mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB53
VRF22
Vibration
suppression
control 2 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the setting of this digit, set "Vibration suppression mode selection" to "3
inertia mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB54
VRF23
Vibration
suppression
control 2 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the setting of this digit, set "Vibration suppression mode selection" to "3
inertia mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
PB55
VRF24
Vibration
suppression
control 2 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is "Automatic setting
(_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. Set manually for
"Manual setting (_ _ 2 _)".
To enable the setting of this digit, set "Vibration suppression mode selection" to "3
inertia mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......