1. FUNCTIONS AND CONFIGURATION
1 - 26
(c) MR-J4-500A(-RJ)
POINT
The servo amplifier is shown with the front cover open. The front cover cannot
be removed.
(1)
(3)
(2)
(Note)
(8)
(4)
Side
(5)
(6)
(7)
The broken line area is the same as
MR-J4-200A(-RJ) or less.
No. Name/Application
Detailed
explanation
(1)
Control circuit terminal block (TE2)
Used to connect the control circuit power supply.
Section 3.1
Section 3.3
(2)
Main circuit terminal block (TE1)
Connect the input power supply.
(3)
Battery holder
Install the the battery for absolute position data
backup.
Section
12.2
(4) Rating
plate
Section 1.6
(5)
Regenerative option/power factor improving reactor
terminal block (TE3)
Used to connect a regenerative option or a power
factor improving DC reactor.
Section 3.1
Section 3.3
(6)
Servo motor power supply terminal block (TE4)
Connect the servo motor.
(7)
Charge lamp
When the main circuit is charged, this will light up.
While this lamp is lit, do not reconnect the cables.
(8)
Protective earth (PE) terminal
Grounding terminal
Section 3.1
Section 3.3
Note. Lines for slots around the battery holder are omitted from the illustration.
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......