8. TROUBLESHOOTING
8 - 4
No. Name
Detail
No.
Detail name
Stop
method
(Note
2, 3)
Alarm
deactivation
Alarm code
Alarm
reset
Cycling
the
power
CN1
22
(Bit 2)
CN1
23
(Bit 1)
CN1
24
(Bit 0)
Alarm
42
Servo control error
(for linear servo motor and
direct drive motor)
42.1
Servo control error by position deviation
EDB (Note 4)
1 1 0
42.2
Servo control error by speed deviation
EDB (Note 4)
42.3
Servo control error by torque/thrust deviation
EDB (Note 4)
Fully closed loop control error
(for fully closed loop control)
42.8
Fully closed loop control error by position deviation
EDB (Note 4)
42.9
Fully closed loop control error by speed deviation
EDB (Note 4)
42.A
Fully closed loop control error by position deviation
during command stop
EDB (Note
4)
45
Main circuit device overheat
45.1
Main circuit device overheat error 1
SD
(Note 1)
(Note 1)
0 1 1
45.2
Main circuit device overheat error 2
SD
(Note 1)
(Note 1)
46
Servo motor overheat
46.1
Abnormal temperature of servo motor 1
SD
(Note 1)
(Note 1)
0 1 1
46.2
Abnormal temperature of servo motor 2
SD
(Note 1)
(Note 1)
46.3
Thermistor disconnected error
SD
(Note 1)
(Note 1)
46.4
Thermistor circuit error
SD
(Note 1)
(Note 1)
46.5
Abnormal temperature of servo motor 3
DB
(Note 1)
(Note 1)
46.6
Abnormal temperature of servo motor 4
DB
(Note 1)
(Note 1)
47
Cooling fan error
47.1
Cooling fan stop error
SD
0 1 1
47.2
Cooling fan speed reduction error
SD
50 Overload
1
50.1
Thermal overload error 1 during operation
SD
(Note 1)
(Note 1)
0 1 1
50.2
Thermal overload error 2 during operation
SD
(Note 1)
(Note 1)
50.3
Thermal overload error 4 during operation
SD
(Note 1)
(Note 1)
50.4
Thermal overload error 1 during a stop
SD
(Note 1)
(Note 1)
50.5
Thermal overload error 2 during a stop
SD
(Note 1)
(Note 1)
50.6
Thermal overload error 4 during a stop
SD
(Note 1)
(Note 1)
51 Overload
2
51.1
Thermal overload error 3 during operation
DB
(Note 1)
(Note 1)
0 1 1
51.2
Thermal overload error 3 during a stop
DB
(Note 1)
(Note 1)
52 Error
excessive
52.1
Excess droop pulse 1
SD
1 0 1
52.3
Excess droop pulse 2
SD
52.4
Error excessive during 0 torque limit
SD
52.5
Excess droop pulse 3
EDB
54
Oscillation
detection
54.1 Oscillation detection error
EDB
0 1 1
56
Forced stop error
56.2
Over speed during forced stop
EDB
1 1 0
56.3
Estimated distance over during forced stop
EDB
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......