
11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 79
(b) 400 V class
Table 11.2 Wire size selection example (HIV wire)
Servo amplifier
Wires
[mm
2
] (Note 1)
1) L1/L2/L3/
2) L11/L21
3) P+/C
4) U/V/W/
(Note 3)
MR-J4-60A4(-RJ)
MR-J4-100A4(-RJ)
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
(Note 4)
2 (AWG14)
AWG 16 to 14
MR-J4-200A4(-RJ)
MR-J4-350A4(-RJ)
MR-J4-500A4(-RJ)
(Note 2)
2 (AWG 14): b
1.25 (AWG 16): a
2 (AWG 14): c
(Note 4)
2 (AWG14): b
3.5 (AWG 12): a
MR-J4-700A4(-RJ)
(Note 2)
3.5 (AWG 12): a
5.5 (AWG 10): a
MR-J4-11KA4(-RJ)
(Note 2)
5.5 (AWG 10): d
1.25 (AWG 16): b
2 (AWG 14): b
(Note 4)
2 (AWG14): f
8 (AWG 8): g
MR-J4-15KA4(-RJ)
(Note 2)
8 (AWG 8): g
3.5 (AWG 12): d
MR-J4-22KA4(-RJ)
(Note 2)
14 (AWG 6): i
3.5 (AWG 12): e
5.5 (AWG 10): e
(Note 5)
8 (AWG 8):h
(Note 6)
14 (AWG 6): i
Note 1. Alphabets in the table indicate crimping tools. For crimp terminals and applicable tools, refer to (2)
in this section.
2. To connect these models to a terminal block, be sure to use the screws that come with the
terminal block.
3. The wire size shows applicable size of the servo amplifier connector and terminal block. For wires
connecting to the servo motor, refer to each servo amplifier instruction manual.
4. Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
5. This is for connecting to the linear servo motor with natural cooling method.
6. This is for connecting to the linear servo motor with liquid cooling method.
Use wires (5)) of the following sizes with the power regeneration converter (FR-RC-H).
Model Wire
[mm
2
]
FR-RC-H15K
14 (AWG6)
FR-RC-H30K
FR-RC-H55K
(c) 100 V class
Table 11.3 Wire size selection example (HIV wire)
Servo amplifier
Wires
[mm
2
]
1) L1/L2/
2) L11/L21
3) P+/C
4) U/V/W/
(Note 1)
MR-J4-10A1(-RJ)
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
(Note 2)
2 (AWG 14)
AWG 18 to 14
(Note 2)
MR-J4-20A1(-RJ)
MR-J4-40A1(-RJ)
Note 1. The wire size shows applicable size of the servo amplifier connector and terminal block. For wires
connecting to the servo motor, refer to each servo amplifier instruction manual.
2. Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......