15. USING A LINEAR SERVO MOTOR
15 - 7
CAUTION
Do not modify the equipment.
The cables such as power wires deriving from the primary side cannot stand the
long-term bending action. Avoid the bending action by fixing the cables to the
moving part, etc. Also, use the cable that stands the long-term bending action for
the wiring to the servo amplifier.
This section does not describe the following items. For details of the items, refer to each section of the
detailed description field.
Item Detailed
explanation
Input power supply circuit
Section 3.1
Explanation of power supply system
Section 3.3
Signal (device) explanations Section
3.5
Alarm occurrence timing chart
Section 3.8
Interface Section
3.9
Grounding Section
3.11
Display and operation sections
Section 4.5
15.3 Operation and functions
15.3.1 Startup
POINT
When using the linear servo motor, set [Pr. PA01] to "_ _ 4 _".