16. USING A DIRECT DRIVE MOTOR
16 - 5
16.3.1 Startup procedure
Start up the direct drive servo in the following procedure.
Set "_ _ _ 1" in [Pr. PA03].
Release [AL. 25 Absolute position
erased]. (Note 5)
Absolute position detection system
Installation and wiring
Turn on the Z-phase pulse of the
direct drive motor by using the
JOG operation of controller. (Note 1, 2)
Perform the magnetic pole detection.
(Note 6)
Transfer of absolute position data
(Refer to section 16.4.)
Absolute position
detection system?
Incremental system
Can you manually turn on
the Z-phase pulse of the direct
drive motor?
Change the setting to disable the
magnetic pole detection.
(Refer to section 16.3.2.)
Turn on the Z-phase pulse of the
direct drive motor manually. (Note 3)
Positioning operation check using the controller (Refer to section 16.3.3.)
Home position return operation (Refer to the controller manual used.)
Positioning operation
Perform the magnetic pole detection. (Refer to section 16.3.2.) (Note 1, 4)
Positioning operation check using the test operation mode (Note 1, 4)
No
Release [AL. 93 ABS data transfer
warning]. (Note 7)
No
Yes
Perform this procedure once at startup.
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......