11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 16
(3) MR-J4-11KA(-RJ) to MR-J4-22KA(-RJ)/MR-J4-11KA4(-RJ) to MR-J4-22KA4(-RJ) (when using the
supplied regenerative resistor)
CAUTION
The regenerative resistor supplied with 11 kW to 22 kW servo amplifiers does not
have a protect cover. Touching the resistor (including wiring/screw hole area) may
cause a burn injury and electric shock. Even if the power was shut-off, be careful
until the bus voltage discharged and the temperature decreased because of the
following reasons.
It may cause a burn injury due to very high temperature without cooling.
It may cause an electric shock due to charged capacitor of the servo amplifier.
When using the regenerative resistors supplied to the servo amplifier, the specified number of resistors
(4 or 5 resistors) must be connected in series. If they are connected in parallel or in less than the
specified number, the servo amplifier may become faulty and/or the regenerative resistors burn.
Install the resistors at intervals of about 70 mm. Cooling the resistors with two cooling fans (1.0 m
3
/min
or more, 92 mm × 92 mm) improves the regeneration capability. In this case, set "_ _ F A" in [Pr. PA02].
P+
C
Servo amplifier
Cooling fan
(Note)
Series connection
5 m or shorter
Note. The number of resistors connected in series depends on the resistor type. The
thermal sensor is not mounted on the attached regenerative resistor. An abnormal
heating of resistor may be generated at a regenerative circuit failure. Install a thermal
sensor near the resistor and establish a protective circuit to shut off the main circuit
power supply when abnormal heating occurs. The detection level of the thermal
sensor varies according to the settings of the resistor. Set the thermal sensor in the
most appropriate position on your design basis, or use the thermal sensor built-in
regenerative option. (MR-RB5R, MR-RB9F, MR-RB9T, MR-RB5K-4, or MR-RB6K-4)
Servo amplifier
Regenerative resistor
Regenerative power [W]
Resultant
resistance
[
Ω
]
Number of
resistors
Normal Cooling
MR-J4-11KA(-RJ) GRZG400-0.8
Ω
500 800 3.2
4
MR-J4-15KA(-RJ) GRZG400-0.6
Ω
850 1300
3
5
MR-J4-22KA(-RJ) GRZG400-0.5
Ω
2.5
MR-J4-11KA4(-RJ) GRZG400-2.5
Ω
500 800
10
4
MR-J4-15KA4(-RJ)
MR-J4-22KA4(-RJ)
GRZG400-2
Ω
850 1300 10
5
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......