5. PARAMETERS
5 - 64
5.2.7 Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ])
POINT
Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ]) cannot be used
with MR-J4-03A6 servo amplifiers.
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PL01
*LIT1
Linear servo
motor/DD
motor
function
selection 1
_ _ _ x Linear servo motor/DD motor magnetic pole detection selection
The setting value "0" will be enabled only with absolute position linear encoders.
0: Magnetic pole detection disabled
1: Magnetic pole detection at first servo-on
5: Magnetic pole detection at every servo-on
1h
_ _ x _ For manufacturer setting
0h
_ x _ _ Stop interval selection at the home position return
Set a stop interval of the home position returning.
The digit is enabled only for linear servo motors.
0: 2
13
(= 8192) pulses
1: 2
17
(= 131072) pulses
2: 2
18
(= 262144) pulses
3: 2
20
(= 1048576) pulses
4: 2
22
(= 4194304) pulses
5: 2
24
(= 16777216) pulses
6: 2
26
(= 67108864) pulses
3h
x _ _ _ For manufacturer setting
0h
PL02
*LIM
Linear
encoder
resolution -
Numerator
Set a linear encoder resolution per µm with [Pr. PL02] and [Pr. PL03].
Set the numerator in [Pr. PL02].
This is enabled only for linear servo motors.
Setting range: 1 to 65535
1000
[
μ
m]
PL03
*LID
Linear
encoder
resolution -
Denominator
Set a linear encoder resolution per µm with [Pr. PL02] and [Pr. PL03].
Set the denominator in [Pr. PL03].
This is enabled only for linear servo motors.
Setting range: 1 to 65535
1000
[
μ
m]
PL04
*LIT2
Linear servo
motor/DD
motor
function
selection 2
_ _ _ x [AL. 42 Servo control error] detection function selection
Refer to the following table.
3h
Setting
value
Torque/thrust
deviation error (Note)
Speed deviation
error (Note)
Position deviation
error (Note)
0
Disabled
Disabled
1
Disabled
Enabled
2
Enabled
Disabled
3
Enabled
4
Disabled
Disabled
5
Enabled
Enabled
6
Enabled
Disabled
7
Enabled
Note. Refer to chapter 15 and 16 for details of each deviation error.
_ _ x _ For manufacturer setting
0h
_ x _ _ For manufacturer setting
0h
x _ _ _ [AL. 42 Servo control error] detection function controller reset condition selection
0: Reset disabled (reset by powering off/on enabled)
1: Reset enabled
0h
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......