5. PARAMETERS
5 - 25
5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PB01
FILT
Adaptive
tuning mode
(adaptive
filter II)
_ _ _ x Filter tuning mode selection
Set the adaptive filter tuning.
Select the adjustment mode of the machine resonance suppression filter 1. Refer to
section 7.1.2 for details.
0: Disabled
1: Automatic setting (Do not use this in the torque control mode.)
2: Manual setting
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PB02
VRFT
Vibration
suppression
control tuning
mode
(advanced
vibration
suppression
control II)
_ _ _ x Vibration suppression control 1 tuning mode selection
Select the tuning mode of the vibration suppression control 1. Refer to section 7.1.5
for details.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _ Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression control 2. To enable the setting
of this digit, set "Vibration suppression mode selection" to "3 inertia mode (_ _ _ 1)"
in [Pr. PA24]. Refer to section 7.1.5 for details.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PB03
PST
Position
command
acceleration/
deceleration
time constant
(position
smoothing)
Set the constant of a primary delay to the position command.
You can select a control method from "Primary delay" or "Linear
acceleration/deceleration" in [Pr. PB25 Function selection B-1]. When the linear
acceleration/deceleration is selected, the setting range is 0 ms to 10 ms. Setting of
longer than 10 ms will be recognized as 10 ms.
When the linear acceleration/deceleration is selected, do not set the "Control mode
selection" ([Pr. PA01]) to the setting other than "_ _ _ 0". Doing so will cause the
servo motor or linear servo motor to make a sudden stop at the time of position
control mode switching or restart.
(Example) When a command is given from a synchronizing encoder, synchronous
operation will start smoothly even if it start during line operation.
Synchronizing
encoder
Start
Servo motor
Servo amplifier
ON
OFF
With time
constant setting
Without time
constant setting
Servo motor
speed
Start
t
Setting range: 0 to 65535
0
[ms]
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......