5. PARAMETERS
5 - 40
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PC13
TLC
Analog
torque/thrust
command
maximum
output
Set the output torque/thrust at the analog torque/thrust command voltage (TC = ±8
V) of +8 V on the assumption that the maximum torque/thrust is 100.0%.
For example, set 50.0.
The maximum torque or thrust ×
50.0
100.0
is outputted.
When you input a command value of the maximum torque/thrust or more to TC, the
value is clamped at the maximum torque/thrust.
Setting range: 0.0 to 1000.0
100.0
[%]