8. TROUBLESHOOTING
8 - 3
No. Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Cycling
the
power
CN1
22
(Bit 2)
CN1
23
(Bit 1)
CN1
24
(Bit 0)
Alarm
21
Encoder normal
communication error 2
21.1
Encoder data error 1
EDB
1 1 0
21.2
Encoder data update error
EDB
21.3
Encoder data waveform error
EDB
21.4
Encoder non-signal error
EDB
21.5
Encoder hardware error 1
EDB
21.6
Encoder hardware error 2
EDB
21.9
Encoder data error 2
EDB
24
Main circuit error
24.1
Ground fault detected by hardware detection
circuit
DB
1 0 0
24.2
Ground fault detected by software detection
function
DB
25
Absolute position erased
25.1
Servo motor encoder - Absolute position erased
DB
1 1 0
27
Initial magnetic pole detection
error
27.1
Initial magnetic pole detection - Abnormal
termination
DB
1 1 0
27.2
Initial magnetic pole detection - Time out error
DB
27.3
Initial magnetic pole detection - Limit switch error
DB
27.4
Initial magnetic pole detection - Estimated error
DB
27.5
Initial magnetic pole detection - Position deviation
error
DB
27.6
Initial magnetic pole detection - Speed deviation
error
DB
27.7
Initial magnetic pole detection - Current error
DB
28
Linear encoder error 2
28.1
Linear encoder - Environment error
EDB
1 1 0
2A
Linear encoder error 1
2A.1
Linear encoder error 1-1
EDB
1 1 0
2A.2
Linear encoder error 1-2
EDB
2A.3
Linear encoder error 1-3
EDB
2A.4
Linear encoder error 1-4
EDB
2A.5
Linear encoder error 1-5
EDB
2A.6
Linear encoder error 1-6
EDB
2A.7
Linear encoder error 1-7
EDB
2A.8
Linear encoder error 1-8
EDB
2B
Encoder counter error
2B.1
Encoder counter error 1
EDB
1 1 0
2B.2
Encoder counter error 2
EDB
30 Regenerative
error
30.1
Regeneration heat error
DB
(Note 1)
(Note 1)
0 0 1
30.2
Regeneration signal error
DB
(Note 1)
(Note 1)
30.3
Regeneration feedback signal error
DB
(Note 1)
(Note 1)
31 Overspeed 31.1
Abnormal
motor
speed
SD
1 0 1
32 Overcurrent
32.1
Overcurrent detected at hardware detection circuit
(during operation)
DB
1 0 0
32.2
Overcurrent detected at software detection
function (during operation)
DB
32.3
Overcurrent detected at hardware detection circuit
(during a stop)
DB
32.4
Overcurrent detected at software detection
function (during a stop)
DB
33
Overvoltage
33.1
Main circuit voltage error
EDB
0 0 1
35
Command frequency error
35.1
Command frequency error
SD
1 0 1
37 Parameter
error
37.1
Parameter setting range error
DB
0 0 0
37.2
Parameter combination error
DB
3A
Inrush current suppression
circuit error
3A.1
Inrush current suppression circuit error
EDB
0 0 0
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......