5. PARAMETERS
5 - 59
5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PE01
*FCT1
Fully closed
loop function
selection 1
_ _ _ x Fully closed loop function selection
The fully closed loop function is selected.
0: Always enabled
1: Switching with CLD (Fully closed loop control selection)
0h
Selection
using
the fully closed loop control
selection (CLD)
Control method
Off
Semi closed loop control
On
Fully closed loop control
To enable the setting, select "Fully closed loop control mode (_ _ 1 _)" of "operation
mode selection" in [Pr. PA01].
Selecting the "switching with CLD (Fully closed loop control selection)" will trigger
[AL. 37] while "absolute position detection system selection" is "Enabled (absolute
position detection system by DIO) (_ _ _ 1)" in [Pr. PA03] .
This digit is not available with MR-J4-03A6 servo amplifiers.
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PE03
*FCT2
Fully closed
loop function
selection 2
_ _ x x Fully closed loop control error detection function selection
Select the fully closed loop control error detection function.
This digit is not available with MR-J4-03A6 servo amplifiers.
: Error detection enabled -: Error detection disabled
03h
Setting
value
Speed
deviation error
Position deviation error
During
servo-on
During servo-
off
With command
Command 0
_ _ 0 0
-
-
-
-
_ _ 0 1
- - -
_ _ 0 2
-
_ _ 0 3
_ _ 1 0
-
-
-
-
_ _ 1 1
- - -
_ _ 1 2
-
-
-
_ _ 1 3
-
-
_ _ 2 0
-
-
-
-
_ _ 2 1
- - -
_ _ 2 2
-
-
_ _ 2 3
-
_ x _ _ For manufacturer setting
0h
x _ _ _ Fully closed loop control error reset selection
0: Reset disabled (reset by powering off/on enabled)
1: Reset enabled
This digit is not available with MR-J4-03A6 servo amplifiers.
0h
PE04
*FBN
Fully closed
loop control -
Feedback
pulse
electronic gear
1 - Numerator
Set a numerator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
Set the electronic gear so that the number of servo motor encoder pulses for one
servo motor revolution is converted to the resolution of the load-side encoder.
This parameter is not available with MR-J4-03A6 servo amplifiers.
Setting range: 1 to 65535
1
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......