18. MR-J4-03A6 SERVO AMPLIFIER
18 - 39
(b) When the forced stop deceleration function is not enabled
ON (no alarm)
OFF (alarm)
MBR
(Electromagnetic
brake interlock)
ON
OFF
Base circuit
(Energy supply to
the servo motor)
ON
OFF
Servo amplifier
display
0 r/min
Servo motor speed
No alarm
Alarm No.
Braking by the dynamic brake
Dynamic brake
+ Braking by the electromagnetic brake
Operation delay time of the electromagnetic brake
Alarm occurrence
ALM (Malfunction)
Braking by the electromagnetic brake
Dynamic brake operating time
(2) When you do not use the forced stop deceleration function
POINT
To disable the function, set "0 _ _ _" in [Pr. PA04].
The operation status during an alarm is the same as (1) (b) of this section.