5. PARAMETERS
5 - 19
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PA13
*PLSS
Command
pulse input
form
Table 5.3 Command input pulse train form selection
Setting
value
Pulse train form
Forward rotation
(positive direction)
command
Reverse rotation
(negative direction)
command
_ _ 10h
Negative logic
Forward rotation
pulse train
(positive direction
pulse train)
Reverse rotation
pulse train
(negative direction
pulse train)
NP
PP
_ _ 11h
Signed pulse train
PP
L
H
NP
_ _ 12h
A-phase pulse
train
B-phase pulse
train
PP
NP
_ _ 00h
Positive logic
Forward rotation
pulse train
(positive direction
pulse train)
Reverse rotation
pulse train
(negative direction
pulse train)
NP
PP
_ _ 01h
Signed pulse train
L
H
PP
NP
_ _ 02h
A-phase pulse
train
B-phase pulse
train
PP
NP
Arrows in the table indicate the timing of importing pulse trains. A-phase and B-phase pulse trains are imported after
they have been multiplied by 4.
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......