11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 94
(c) Cable clamp fitting AERSBAN-_SET
Generally, the grounding of the shielded wire may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an grounding plate as
shown below.
Install the grounding plate near the servo amplifier for the encoder cable.Peel part of the cable
sheath to expose the external conductor, and press that part against the grounding plate with the
cable clamp. If the cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the grounding plate.
[Unit: mm]
Cable clamp
(A, B)
Cable
Earth plate
External conductor
Clamp section diagram
40
Strip the cable sheath of
the clamped area.
cutter
cable
Dimensions
[Unit: mm]
Earth plate
(Note) M4 screw
11
3
6
C
A
6
22
17.5
35
35
7
24
0 -0.
2
B ± 0.3
2-
φ
5 hole
installation hole
[Unit: mm]
Clamp section diagram
L or less
10
30
24
+ 0.
3
0
Note. Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model A
B
C
Accessory
fittings Clamp
fitting L
AERSBAN-DSET
100
86
30
Clamp A: 2 pcs.
A
70
AERSBAN-ESET
70
56
Clamp B: 1 pc.
B
45
Содержание MR-J4
Страница 9: ...A 8 MEMO ...
Страница 19: ...10 MEMO ...
Страница 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Страница 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Страница 199: ...4 STARTUP 4 44 MEMO ...
Страница 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Страница 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Страница 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Страница 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Страница 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Страница 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Страница 763: ...APPENDIX App 38 ...
Страница 789: ...MEMO ...
Страница 793: ......