Detailed Directions
373
5. Type the key for the specific option in the box.
Once the option is enabled, the key is displayed, and a
Disable
button replaces the
Enable
button.
Configuring Power Supply Redundancy on a Kaleido-X16
Power supply redundancy is an option on the Kaleido-X16, which can ship with a single PSU. In order to
avoid having the system dashboard display unnecessary alarms, there is a check box in XAdmin to indicate
the presence of the second PSU. By default, this option is selected (both PSUs are monitored). Removing
the check mark will stop the monitoring of alarms for PSU B (its status is set to disabled, and therefore will
not appear on the dashboard).
Location of Slot A and Slot B in the front of the Kaleido-X16 frame
To configure the PSU B Installed option in XAdmin:
1. Open a Web browser window and type the IP address of the Kaleido-X16 frame in the address bar.
Example:
To activate the Extraction of CC, Subtitling and XDS metadata option (CC/XDS Option) for a
Kaleido-X input card, you would need to locate the appropriate card in XAdmin’s Status and Options
page, and enter the key.
Notes
• One CC/XDS Option key is needed per input card, and the extraction of CC 608, CC 708, XDS and
Subtitling WST metadata are all activated as a single option.
• After enabling the 3D Support option in XAdmin, refresh the current layout or load another one,
for the change to be reflected on the monitor wall.
Slot A
Slot B
PSU A
removed from
Slot A
Содержание Kaleido-X
Страница 1: ...Kaleido X User s Manual Part Number M770 2800 111 1 June 2011 ...
Страница 8: ...viii toc ...
Страница 33: ...Loading a Layout 25 Kaleido X16 ...
Страница 34: ...26 Getting Started 2 Kaleido X 4RU ...
Страница 152: ...144 Creating Logical Sources 7 ...
Страница 178: ...170 Setting Up Rooms 8 ...
Страница 244: ...236 Creating Layouts 9 ...
Страница 253: ...Detailed Directions 245 3 Under Properties General type a Friendly name for the Action ...
Страница 256: ...248 Creating Actions 10 ...
Страница 272: ...264 Managing Kaleido RCP2 Users 11 ...
Страница 348: ...340 Tally Interface Devices 13 ...
Страница 350: ......
Страница 352: ...344 Using the Serial to TCP IP Dispatcher 15 ...
Страница 406: ...398 Index ...