Configuring UMDs
215
mechanism. An alarm latch will keep the error state visible until someone acknowledges the associated
alarm. For UMDs, the latch color can be set to follow the background or the text color configuration.
To set the alarm reporting features for a UMD (text and tallies):
1. In XEdit, open a layout and click the UMD whose alarm reporting behavior you wish to configure.
2. In the
Properties
pane, scroll down to the
Alarms/Tallies
section, to set the appropriate text and
background color scheme.
3. Click the
Blink mode
boxes, and then select the appropriate blinking behavior, for your purposes:
Blink mode
Description
Off
The status indicator will never blink.
Follow latch
The status indicator’s blinking will follow the latch status. The indicator will
blink until someone unlatches the alarm.
Critical
The status indicator will blink when the current status is critical.
Critical and major
The status indicator will blink when the current status is critical or major.
Critical, major and minor
The status indicator will blink when the current status is critical, major or minor.
Blink mode selection
Display alarm latch check box
Display alarm latch check box
Display alarm latch check box
Blink mode selection
Blink mode selection
Latch colors selection
Содержание Kaleido-X
Страница 1: ...Kaleido X User s Manual Part Number M770 2800 111 1 June 2011 ...
Страница 8: ...viii toc ...
Страница 33: ...Loading a Layout 25 Kaleido X16 ...
Страница 34: ...26 Getting Started 2 Kaleido X 4RU ...
Страница 152: ...144 Creating Logical Sources 7 ...
Страница 178: ...170 Setting Up Rooms 8 ...
Страница 244: ...236 Creating Layouts 9 ...
Страница 253: ...Detailed Directions 245 3 Under Properties General type a Friendly name for the Action ...
Страница 256: ...248 Creating Actions 10 ...
Страница 272: ...264 Managing Kaleido RCP2 Users 11 ...
Страница 348: ...340 Tally Interface Devices 13 ...
Страница 350: ......
Страница 352: ...344 Using the Serial to TCP IP Dispatcher 15 ...
Страница 406: ...398 Index ...