7. WEB Control Application
7-16
7.6 Function Code of WEB Application Group (WEB_[][])
Code
No.
Comm.
Addr
Code Name
LCD DISPLAY
Setting Data
Adjustment
During Run
PAGE
Range
Unit
Default
WEB_00
-
Selection of Function Code
Jump Code
1 ~ 59
Yes
WEB_01
7C01
Diameter Size Display
Diameter
5.0 ~ 100.0
%
10.0
No
7-18
WEB_02
7C02
Selected Initial Diameter
Current Core
(Display Only)
0 (Diam Preset 1)
1 (Diam Preset 2)
2 (Diam Preset 3)
3 (Diam Preset 4)
4 (Analog)
5 (Option)
0 (Diam Preset 1)
No
7-18
WEB_03
7C03
Setting of the Type of
Diameter Initialization
DiaPresetSrc
0 (Keypad)
1 (Analog)
2 (Option)
0 (Keypad)
No
7-18
WEB_04
7C04
1
st
Diameter Initial Value
Diam Preset 1
WEB_10 ~ 100.0
%
10.0
No
7-20
WEB_05
7C05
2nd Diameter Initial Value
Diam Preset 2
WEB_10 ~ 100.0
%
15.0
No
7-20
WEB_06
7C06
3rd Diameter Initial Value
Diam Preset 3
WEB_10 ~ 100.0
%
20.0
No
7-20
WEB_07
7C07
4th Diameter Initial Value
Diam Preset 4
WEB_10 ~ 100.0
%
25.0
No
7-20
WEB_08
7C08
Motor Maximum Rotating
Speed with Min. Diameter
MaxMotor SPD
75.0 ~ 3600.0
rpm
300.0
Yes
7-21
WEB_09
7C09
Minimum
Effective
Line
Speed
MinLine SPD
0.0 ~ 100.0
%
5.0
No
7-21
WEB_10
7C0A
Minimum Diameter
Min Diameter
5.0 ~ 100.0
%
10.0
No
7-22
WEB_11
7C0B
Selection
of
Acceleration/Deceleration
Time Setting in case of WEB
Control
AccDecWeb
0 (No) / 1 (Yes)
1 (Yes)
No
7-22
WEB_12
7C0C
Acceleration Time in case of
WEB Control
Acc TimeWeb
0.00 ~ 6000.0
sec
0.50
Yes
7-22
WEB_13
7C0D
deceleration Time in case of
WEB Control
Dec TimeWeb
0.00 ~ 6000.0
sec
0.50
Yes
7-22
WEB_14
7C0E
Setting of the Type of
Diameter Computation
Diameter Src
0 (Internal)
1 (Exernal)
0 (Internal)
No
7-22
WEB_15
7C0F
Time Constant of Diameter
Computation LPF
Diameter LPF
0.01 ~ 300.00
sec
5.00
Yes
7-23
WEB_16
7C10
False Core Value
False Core
0.0 ~ 50.0
%
5.0
Yes
7-23
WEB_17
7C11
Rewind/Unwind Setting
Re/Un Wind
0 (Rewind)
1 (Unwind)
0 (Rewind)
No
7-23
WEB_18
7C12
Overwind
/Underwind
Setting
O/U Wind
0 (Overwind)
1 (Underwind)
0 (Overwind)
No
7-24
WEB_19
7C13
Tension Reference Input
Setting
TensionInput
-100.0 ~ 100.0
%
0.0
Yes
7-26
WEB_20
7C14
Taper Type Setting
Taper Type
0 (None)
1 (Hyperbolic)
2 (Linear)
0 (None)
No
7-26
WEB_21
7C15
Taper Input Value Setting
Taper Input
-100.0 ~ 100.0
%
0.0
No
7-26
WEB_22
7C16
Boost Type Setting
Boost Type
0 (Proportional)
1 (Fixed)
0 (Proportional)
No
7-27
WEB_23
7C17
Boost Input Value Setting
Boost Input
0.0 ~ 50.0
%
0.0
No
7-27
WEB_24
7C18
Stall Type Setting
Stall Type
0 (Proportional)
1 (Fixed)
0 (Proportional)
No
7-28
WEB_25
7C19
Stall Input Value Setting
Stall Input
0.0 ~ 50.0
%
0.0
No
7-28
WEB_26
7C1A
Ramp Time Setting of
Tension Reference Input
Value
Tension Ramp
0.00 ~ 600.00
sec
5.00
Yes
7-29
WEB_27
7C1B
Tension
Control
Enable
Setting
Tension Enb
0 (Disable)
1 (Enable)
1 (Enable)
No
7-30
WEB_28
7C1C
PID Reference Type Setting
PIDRef Sel
0 (Dancer Pos)
1 (Taper Out)
1 (Taper Out)
No
7-30
WEB_29
7C1D
Dancer Reference position
Setting
Dancer Pos
-100.0 ~ 100.0
%
0.0
Yes
7-31
WEB_30
7C1E
Process PID P1 Gain Setting
ProcPID Kp1
0.0 ~ 999.9
%
10.0
Yes
7-31
WEB_31
7C1F
Process PID P2 Gain Setting
ProcPID Kp2
0.0 ~ 999.9
%
0.0
Yes
7-31
WEB_32
7C20
Process PID I1 Gain Setting
ProcPID Ki1
0.0 ~ 100.0
sec
5.0
Yes
7-31
WEB_33
7C21
Process PID I2 Gain Setting
ProcPID Ki2
0.0 ~ 100.0
sec
0.0
Yes
7-31
Содержание LSLV-iV5 Series
Страница 59: ...4 Trial Operation 4 17 ...
Страница 285: ......