6. Function Description
6-35
LCD display
Description
Tuning
time
tuning. If the problem persists, contact LS
representative.
3) Standstill auto tuning
3.1) Precaution
Be sure to lock the motor shaft using magnetic brake to find motor parameters correctly.
3.2) Parameter setting
LCD display
Description
Setting range
Unit
Factory
setting
PAR_23 AutoTuneType
Auto tuning type selection
Rotational
StandStill
StandStill
PAR_24
Auto Tuning
Auto tuning range setting
None
ALL1
Rs Tuning
Lsigma
If/Tr/Ls Tune
Inertia Tuning
None
There are 4 modes for Standstill auto-tuning.
ALL1: Rs
Lsigma
If
Ls
Tr
Rs Tuning, Lsigma, If/Tr/Ls Tune: Perform each parameter seperately. Encoder test is not performed. PAR_25 Inertia
Tuning will be displayed when PAR_35 is Yes.
Auto-tuning
type
Description
None
No Operation
ALL1
Rs, L
If/Tr/Ls are tuned continuously except Encoder Test
Rs Tuning
Rs tuning Only. The stator resistance is tuned at standstill.
Lsigma
L
tuning Only. The Leakage Inductance is tuned at standstill.
If/Tr/Ls Tune
Finds If/Tr/Ls by applying DC current pulse. It finds magnetizing current, secondary
constant of motor and first inductance concurrently.
Inertia Tuning
It finds Inertial constant after operating motor to forward/reverse operation with one third
base speed.
FWD/REV LEDs are blinking during auto-tuning.
PA R
▶
Auto tuning
2 5 [ ] [ ] E r r o r