6. Function Description
6-68
CON_33
set value
Positive Torque Limit
Negative Torque Limit
Regenerating
Torque Limit
Ax Kpd Ax
Vx
CON_30
Vx
Ax Ax Kpd
Vx
Vx
CON_31
Ax Ax Ax
Vx
Vx
Vx
Opt Opt Opt
Positive Torque Limit of
Option
Negative Torque Limit of
Option
Regenerating Torque Limit
of Option
485 485 485
Positive Torque Limit of 485
Negative Torque Limit of
485
Regenerating Torque Limit
of 485
※
Vx marks the Torque Limit value defined in analog input terminal.
7) Torque Current reference
The torque reference is converted to the torque current reference. The torque current reference is generated from the
rated current and magnetizing current of the motor. The initial value of the rated current and magnetizing current of
the motor can be set by OTIS vector motor parameter that is chosen at PAR_07
Code
LCD display
Description
Setting range
Unit
Factory setting
PAR_07
Motor Select
Motor capacity selection
2.2 ~ 375.0
kW
PAR_22
Rated-Curr
Motor rated current
1.0 ~ 2000.0
A
PAR_27
Flux-Curr
Motor flux current
0.0 ~ 70% of PAR_22
A
8) Torque limit by Speed limit
This function limits torque when the speed reaches a certain level duing operation in torque mode. The torque
limitation is shown in the figure below.
CON_80
CON_79
Torque Ref
Torque
Speed
Code
LCD display
Description
Setting range
Unit
Factory setting
CON_79
Spd Lmt Src
Speed limit of
Speed/Torque switching
0.1 ~ Max Speed
rpm
CON_80
SpdLmtBias
Speed bias of
Speed/Torque
100.0 ~ Max Speed
rpm