3. Installation and Wiring
3-6
AC Power Input Type
SV022, 037, 055, 075, 110, 150, 185, 220iV5-2(DB)
SV022, 037, 055, 075, 110, 150, 185, 220iV5-4(DB)
PE
R
S
T
G
U
V
W
B1
B 2
FX
P1( MM0)
P2( MM1)
P3(ATO)
CM
VREF
AI 1
5G
IM
3
P
AC
input
(220/440V)
(50/ 60Hz)
GE
A +
RA
GE
RB
E
GE
MC
MCCB
Multi - function input 1
Multi - function input 2
Multi - function input 3
Common
Potentiometer
10 k ohm , 1/ 2W
Multi -function input
DB Resistor
(optional )
G
Encoder A
Phase input
Note) :
Main circuit
,
: Control circuit
Shield
P4( FHM)
P5( BAT)
P6( BRC)
P7( MCC)
STARVERT - iV5
Multi - function input 4
Multi - function input 5
Multi - function input 6
Multi - function input 7
AI 2
AI 3
Power supply (+10 V)
Analog input 1
Analog input 2
Analog input 3
Common
Analog input
(10 ~ -10V)
(- 10 ~ 10 V)
( 0 ~ 10V)
(10 ~ 0V)
( 0 ~ 20 mA)
( 20 ~ 0mA)
( Motor NTC /PTC)
Encoder B
Phase input
Power supply (5V)
Common (0V)
Open collector
output
ACR
AO 1
AO 2
5G
Analog output 1
Analog output 2
Common
Analog
output
(-10 ~ 10V)
( 10 ~ -10V)
( 0 ~ 10V)
(10 ~ 0V)
30 A
30 C
30 B
1A
1B
2B
2A
Fault relay output
( ~ AC 250V, 1A)
( ~ DC 30 V, 1A)
Auxiliary relay
output
( ~ AC 250V, 1A)
( ~ DC 30 V, 1A)
Open collector
output
( 24 V, 50mA)
OC1
EG
B +
A -
B -
A phase encoder pulse output
B phase encoder pulse output
Encoder output Common
Encoder output Common
AC 1
AC 2
Aux. power source
for control circuit
Insulated
Trasformer
Note 1)
RX
BX
RST
FWD run /stop command
REV run / stop command
Emergency stop
Fault reset
24 V
(50/60Hz)
(220V)
Encoder
( Line Drive Type)
Note 1) It is used when inverter control circuit is energized from auxiliary power
source (220 VAC) separated from main power supply. Use insulated transformer to
separate from main power supply. (Transformer capacity: Above 100VA
recommended)
Only 11~22kW-2(Press) and 5.5~22kW-4(Press/Mold) supported
(Other products will be released later.)
Main Power Circuit
Control Circuit