Chapter 8 Communication Function
8-19
Address
Parameter
Scale unit R/W
Allotment for Bits
0385h
N/A
0386h
B15 N/A
B14 N/A
B13 N/A
B12 N/A
B11 N/A
B10 N/A
B9
N/A
B8
N/A
B7
N/A
B6
N/A
B5
Relay1 (A
–
1B)
B4
Relay2 (2A
–
2B)
B3
Open collector 1 (OC1
–
EG)
B2
Open collector 2 (OC2
–
EG)
B1
Open collector 3 (OC3
–
EG)
B0
N/A
0387h
N/A
0388h
PID command
0.1
%
R/W PID reference command
0389h
PID feedback
0.1
%
R/W PID feedback value
038Ah
Motor rated current
0.1
A
R/W PAR_22 Rated-Curr
038Bh
Inverter voltage specification
R
200 : 200V 400 : 400V
038Ch~
038Fh
N/A
0390h
Torque Ref
0.1
%
Torque command
1)
0391h
Fwd Pos Torque Limit
0.1
%
R/W Positive torque limit
2)
0392h
Fwd Neg Torque Limit
0.1
%
R/W Positive regeneration torque limit
2)
0393h
Rev Pos Torque Limit
0.1
%
R/W Negative torque limit
2)
0394h
Rev Neg Torque Limit
0.1
%
R/W Negative regeneration torque limit
2)
0395h
Torque Bias
0.1
%
R/W Torque Bias
3)
0396h
~039Dh
N/A
Note 1) It is available to wirte when CON_01 (Control Mote) is Torque and CON_31 (Trq Ref Src) is Option/Int485.
Note 2) It is available to write CON_33 Trq Lmt Src is 485 485 485. If not, it is available to read. .
Note 3) It will be changed only when CON_37 Trq Bias Src is Option/Int485.