6. Function Description
6-62
If the output error of Process PID exists at stopping, it keeps current motor speed during
“
PID Hold Time
”
and then free-
runs and stops by stopping friction power. If output error is
“
0
”
, motor is stopped regardless of
“
PID Hold Time
“
setting.
Code
LCD display
Description
Setting range
Unit
Factory setting
CON_24
PIDHoldTime
Process PID Hold Time
0 ~ 10000
ms
5000
6.5.6 Draw control
Draw control is a sort of Open Loop tension control. Draw is the ratio of speed difference between one roll and the
other. Tension is generated as in the following equation.
V2
V2
-
V1
D
Where,
V1, V2: Transfer speed of each roll (m/min)
T: Tension (kg)
E: Elasticity coefficient of processed material (kg/mm2)
S: Sectional area of processed material (mm2)
2
2
1
V
V
V
S
E
D
S
E
T
Line Speed Setting
IM
INVERTER 2
IM
INVERTER 1
V
2
Draw Setting
V1