5. Function Code Table
5-10
CODE
NO.
Comm.
Addr
CODE NAME
LCD DISPLAY
SETTING DATA
Adjustment
During Run
RANGE
UNIT
DEFAULT
FUN_22 7416
Dwell Time
Dwell Time
0.00 ~ 100.00
sec
0.00
No
FUN_33 7421
Acc./Dec. reference
Speed
Acc/Dec Ref
0 (Max Speed)
1 (Ref Speed)
-
0 (Max
Speed)
No
FUN_36 7424
S ratio 1
in acceleration start
Acc S Start
0.0 ~ 50.0
%
0.0
No
FUN_37 7425
S ratio 2
in acceleration start
Acc S End
0.0
No
FUN_38 7426
S ratio 1
in acceleration start
Dec S Start
0.0
No
FUN_39 7427
S ratio 2
in acceleration start
Dec S End
0.0
No
FUN_40 7428
Time scale of acc./dec.
time
Time scale
0 (0.01 sec)
1 (0.1 sec)
-
0.0
No
FUN_41 7429
Acceleration time 1
Acc Time-1
0.00 ~ 6000.0
sec
2.00
2)
Yes
FUN_42 742A Deceleration time 1
Dec Time-1
2.00
2)
Yes
FUN_43 742B Acceleration time 2
Acc Time-2
3.00
2)
Yes
FUN_44 742C Deceleration time 2
Dec Time-2
3.00
2)
Yes
FUN_45 742D Acceleration time 3
Acc Time-3
4.00
2)
Yes
FUN_46 742E Deceleration time 3
Dec Time-3
4.00
2)
Yes
FUN_47 742F
Acceleration time 4
Acc Time-4
5.00
2)
Yes
FUN_48 7430
Deceleration time 4
Dec Time-4
5.00
2)
Yes
FUN_49 7431
Selection about use of
zero speed time
Use 0 Dec T
0 (No) / 1 (Yes)
-
0 (No)
Yes
FUN_51 7433 Dec.time of zero speed
0 Dec Time
0.00 ~ 6000.0
sec
0.00
Yes
FUN_52 7434
Dec. time of emergent
stop
BX Time
0.0 ~ 6000.0
sec
0.0
Yes
FUN_53 7435
Initial excitation time of
motor
PreExct Time
0 ~ 10000
ms
0
No
FUN_54 7436 Hold time
Hold Time
100 ~ 10000
ms
1000
No
FUN_55 7437
Electronic thermal
Selection
ETH Select
0 (No) / 1 (Yes)
-
0 (No)
Yes
FUN_56 7438
Electronic thermal level
for 1 minute
ETH 1 min
FUN_56 ~ 200
%
150
Yes
FUN_57 7439
Electronic thermal level
for continuous
ETH Cont
50 ~ FUN_55
(Only available to
150%)
%
100
Yes
Содержание LSLV-iV5 Series