2. Specification
2-4
Items
Detailed Specification
Analog input
3 channels
(AI1, AI2, AI3*, (AI4,AI5: Extended I/O))
-10
10V, 10
10V, 0
10V, 10
0V,0
20mA,
20
0mA, Motor NTC (*Only AI3(AI5:Extended I/O)
selectable)
Selectable among 17 different user-defined
functions
AI3(AI5): Motor NTC only available with Higen
motors
Contact input
FX, RX, BX, RST, P1 ~ P7
Selectable among 46 different user-defined input
functions
Output
Analog output
2 channels (AO1, AO2)
-10V
10V, 10
-10V, 0
10V,
10
0V output
Selectable among 39 different user-defined
functions
Contact output
2 channels (1A-1B, 2A-2B)
Fault alarm relay: 1 channel (30A-30C, 30B-30C)
Open Collector
1 Channel (OC1/EG)
Protection
Overcurrent, Overvoltage, Low voltage, Inverter
overheat, Inverter thermal sensor malfunction,
Motor overheat, Motor thermal sensor malfunction,
Overspeed, Instantaneous IGBT gate block (BX),
Fuse blown open, External Trip, Pulse encoder
malfunction, Electronic thermal function, Inverter
overload, Ground fault current, IGBT short,
Communication error, Input/Output phase open
protection
Environ
ment
Installation condition
Indoor, Free of Corrosive gas and Direct sunlight
(Pollution Degree 2)
Ambient temperature -10 ~ 40
C (Non-frozen condition)
Humidity
Below RH 90% (Dewdrop should not be formed)
Cooling method
Forced ventilation by cooling fan
IP Type
IP00: 2.2 ~ 22 kW (MD), 30 ~ 500kW
IP20: 5.5 ~ 2.2 kW (Press)
Altitude, Vibration
Below 1000m above sea level,
Below 5.9m/s